Construction Details
- Conductor : Circular tinned or bare annealed copper wire
- Fire proof layer (Fir resisting cable only) : Mica glass tape
- Insulation : Cross-linked polyethylene (XLPE)
- Individual core screen : Annealed copper wire braid
- Cabling (with filler)
- Binder tape
- Inner covering : Lapped covering
- Armour : Annealed copper wire braid screen armour
- Outer sheath : Halogen free thermoplastic compound (SHF1)
This product is part of our Shiplink® offer
Standard applied
- Design guideline : IEC 60092-353
- Flame retardant : IEC 60332-3 Cate. 'A'
- Fire resistant : IEC 60331
- Halogen free property : IEC 60754-1, 0.5%↓
- Low smoke property : IEC 61034-1/2
- Cold resistant : CSA C22.2 No.03 (if necessary)
- Cold bending, -40℃ & Cold impact, -35℃
Certificates Approved
- GL Type approved, CCS Type approved, ETL listed
|