EN 50264-3-1 3.6kV Single core sheathed

Bookmark print Contact Us
EN 50264-3-1 3.6kV Single core sheathed

Flamex® types
3.6/ 6.0 kV
Unscreened and sheathed single core cables

标准
国际标准  EN 50264-1
国家标准  BS 6853; NF F 16-101
产品描述

Applications

Strictly halogen free. All these wires combine the advantages of reduced size, lightweight, high chemical resistance, high mechanical properties.

They are recommended for installation in railway vehicles (locomotives, trains, trolley busses) for power supply.
Current carrying capacity acc. to EN 50343.
Cabling rules accoridng to EN 50355. 

Construction

  1. Conductor
    Flexible stranded tinned copper. Class 5 acc. to IEC 60228. Covered with separator tape 
     
  2. Insulation
    Special cross-linked compound. Type EI 109 acc. to EN 50264-1 
    Color: Black
     
  3. Screen 
    no  
     
  4. Outer sheath 
    Special cross-linked compound. Type EM 104 acc. to EN 50264-1
    Color: Black

 

Cable marking

FLAMEX Z – EN 50264-3-1 –Voltage Rate– (Section) mm² – Hazard Level – Nexans – 370– Week/Year

 

Core colours

Black (BK) 

 

Standards applied

EN 50264-3-1
BS 6853
NF F16-101


 TOP
产品特性
结构特性
无卤 PE sheathed  
导体类型 Stranded  
导体材料 镀锡铜线  
绝缘 Cross-linked compound  
外护套 Cross-linked compound  
颜色  
尺寸特性
芯线数 1  
电气特性
额定电压Uo/U 3.6 / 6 kV  
用法特性
气体腐蚀性 No corrosive EN 50267-2-2  
阻燃 EN 60332-1-2  
气体毒性 Non-toxic EN 50305.9.2  
阻燃 EN 50266-2-4; EN 50266-2-5; EN 50305.9.1.2  
烟密度 EN/IEC 61034-2  
Fuel resistance Yes  
防油  
Ozone resistance  
U.V resistance  
芯线最高静止温度 90°C  
耐化学物质  

 TOP
China SDH 111129 EB 50624-3-1 3.6/6.0kV
Flamex Z single core sheathed

Electrical properties

 

 

Nominal voltage 

Uo/U (Umax) =

3.6/6.0 kV

Max. operating voltage in DC installations, 
one-sided earthed 

Vo =

5.4 kV DC

Testing a.c. voltage (5 minutes) 

U =

11.0 kV 

Max. operationg temperature at conductor

 

 

Conductor at normal operation

 

≤ 90°C 100 000h

 

≤ 120°C 200 000h

Conductor under short-circuit conditions(tinned)

≤ 200°C /5s

Operating in cold

 

 

Min. permissible ambient temperature

 

≥ -40°C

Min. bending radii

 

Fixed installation:
Free moved :

D < 12           D ≥ 12
≥ 3D               ≥ 4D
≥ 4D               ≥ 5D


 TOP
More on EN 50264-3-1

Resistance:

  • Good resistance to UV and humidity
  • Good chemical resistance (acids, oils, ...)

Flame retardant according to

  • EN 60332-1-2
  • EN 50266-2-4
  • EN 50266-2-5
  • EN 50305 9,1.2

 

Low smoke according to EN 61034-2 Light transmittance ≥70%

Halogen free according to EN 50267-2-1 & EN 60684-2

No corrosivity according to EN 50267-2-2 pH≥4.3, conductivity ≤10 S/mm

Non-toxicity according to EN 50305,9.2 Toxicity index ≤3


 TOP