Applications
Strictly halogen free. These wires combine the advantages of small size, lightweight, high chemical resistance, high mechanical properties.
They are recommended for installation in railway vehicles (Locomotives, trains, trolley busses) inside or outside, switching stations and control panels. Current carrying capacity acc. to EN 50343.
Construction
- Conductor :
Flexible stranded tinned copper. Class 5 acc. to IEC 60228. Covered with separator tape
- Insulation :
Special cross-linked compound. Rubber type EI 109 acc. to EN50264-1
- Screen :
Tinned copper wire braid acc. to EN 50264-3-2 with separator tape
- Outer sheath :
Special cross-linked rubber. Type EM104 acc. to EN 50264-1
Bending factor when fixed installed : 5D
Bending factor when dynamic installed : 10D
Operating surroundings temperature: -40°C~85°C
Cable marking
FLAMEX Z – EN 50264-3-2 S 600V– Core number x Conductor Size – Hazard Level (MM)– S – Nexans – Factory Code – Batch
Core colours
Black (BK)
Green/Yellow (GNYE)
Sheath colours
Black (BK)
Standards applied
EN 50264-3-2. EN 45545-1, BS 6853, NF F 16-101
|