Y500S NF F63-826 Single core

Bookmark print Contact Us
Y500S NF F63-826 Single core

Standard wall insulation flexible single core cables

标准
国际标准  IEC 60228
产品描述

Applications

These wires combine the advantages of strictly halogen free, fire retardant, low smoke fume and high mechanical properties.

They are recommended for installation in railway vehicles (Locomotives, trains, trolley busses) inside or outside, switching stations and control panels. Current carrying capacity acc. to NF F 61-012. Cabling rules are given in NF F 61-010.

 

Construction

  1. Conductor :
    Flexible stranded tinned copper. Class 5 acc. to IEC 60228. Covered with separator tape

     
  2. Insulation :
    Special cross-linked, halogen free compound
     
  3. Screen :
    No
     
  4. Outer sheath :
    No

 

Bending factor when fixed installed : 4D

Bending factor when dynamic installed : 5D

Operating surroundings temperature: -40°C~85°C

 

Cable marking

Y 500 S – Conductor Size – NF F 63-826 –Nexans – Factory Code – Batch Number/Year

 

Core colours

Black (BK)

 

Standards applied

NF F 63-826 NF F 16-101
 


 TOP
产品特性
结构特性
颜色  
导体类型 Stranded  
无卤 NF F 63826  
绝缘 Special cross-linked halogen free rubber  
导体材料 镀锡铜线  
用法特性
气体腐蚀性 No corrosive EN 50267-2-2  
阻燃 NFC 32070 C2  
气体毒性 Non-toxic NFF 16101, NFX 70100  
阻燃 NFC 32070 C1, IEC 60332-3-24  
烟密度 NF F 16101, NF X 10702  
防油  
Ozone resistance  
U.V resistance  
Fuel resistance Yes  
芯线最高静止温度 90°C  

 TOP
参数搜索
导线截面  mm²
Conductor diameter (mm)  
Minimum outer diameter  mm
Maximum outer diameter  mm
近似重量  kg/km
Fire load  MJ/km
Apply
Reset
您的选择   7/7
Select all Items 耐克森产品编号 导线截面 (mm²) Conductor diameter (mm) Minimum outer diameter (mm) Maximum outer diameter (mm) 近似重量 (kg/km) Fire load (MJ/km)
Make to order product 51610013 1 1.3 3.8 4.5 28 358
Make to order product 51610007 1.5 1.5 4.1 4.5 33 384
Make to order product 51610008 2.5 1.9 4.5 5.2 44 436
Make to order product 51610009 4 2.5 5.1 5.5 61 514
Make to order product 51610010 6 3.0 5.8 6.5 85 636
Make to order product 51610011 10 4.1 7.1 7.9 135 859
Make to order product 51610012 16 5.3 8.3 9.2 190 1038
Add to favorites

 TOP
Characteristics : Smoke and Toxicity

Gas toxicity

Non-toxic  EN 50305,9 .2 Tocxicity index ≤3

 

 

Gas corrosivity

No corrosive EN 50267-2-2 pH≥4.3, Conductivity ≤10μS/mm 

 

 

Smoke density

Low smoke EN 61034-2 Light transmittance ≥70% 

 

 

Fire retardant

Fire retardant EN 50266-2-4 EN 50266-2-5 EN 50305, 9.1.2


Electrical characteristics

Electrical properties

 

 

Nominal voltage 

Uo/U (Umax) =

330/580 (690) V 

Max. operating voltage in DC installations, 
one-sided earthed 

Vo =

500V DC

Testing a.c. voltage (5 minutes) 

U =

2.5 kV

 

Max. operationg temperature at conductor

 

 

Conductor at normal operation

 

≤ 90 °C/ 100 000 h

 

≤ 105 °C/ 20 000 h

Conductor under short-circuit conditions(tinned)

≤ 200°C/ 5 s 

 

Operating in cold

 

 

Min. permissible ambient temperature

 

≥ -40 °C

 

Min. bending radii

 

Fixed installation:
Free moved : 
D= cable ø (mm)

≥ 4D
≥ 5D
                        


 TOP