English Login Get Registered Catalog Browser Contact Us
耐克森,全球电缆及电缆系统专家

关于耐克森

产品及解决方案

客户服务

耐克森招聘

新闻中心

Go

Y3000S NF F63-827 Single core

Bookmark print Contact Us
Y3000S NF F63-827 Single core

Standard wall insulation flexible single core cables

标准
国际标准  IEC 60228
产品描述

Applications

These wires combine the advantages of strictly halogen free, fire retardant, low smoke fume and high mechanical properties.

They are recommended for installation in railway vehicles (Locomotives, trains, trolley busses) inside or outside, switching stations and control panels. Current carrying capacity acc. to NF F 61-012. Cabling rules are given in NF F 61-010.

 

Construction

  1. Conductor :
    Flexible stranded tinned copper. Class 5 acc. to IEC 60228. Covered with separator tape

     
  2. Insulation :
    Special cross-linked, Halogen free compound
     
  3. Screen :
    No
     
  4. Outer sheath :
    No

 

Bending factor when fixed installed : 4D

Bending factor when dynamic installed : 5D

Operating surroundings temperature: -40°C~115°C

 

Cable marking

Y 3000 S – Conductor Size – NF F 63-827 –Nexans – Factory Code – Batch Number/Year

 

Core colours

Black (BK)

 

Standards applied

NF F 63-827
EN 45545-1
NF F16-101


 TOP
产品特性
结构特性
颜色  
导体类型 Stranded  
无卤 NF F 63827  
绝缘 Special cross-linked halogen free rubber  
导体材料 镀锡铜线  
用法特性
气体腐蚀性 No corrosive EN 50267-2-2  
阻燃 NFC 32070 C2  
气体毒性 Non-toxic NFF 16101, NFX 70100  
阻燃 NFC 32070 C1, IEC 60332-3-24  
烟密度 NF F 16101, NF X 10702  
防油  
Ozone resistance  
U.V resistance  
Fuel resistance Yes  
芯线最高静止温度 90°C  

 TOP
参数搜索
导线截面  mm²
导线直径  mm
Minimum outer diameter  mm
Maximum outer diameter  mm
近似重量  kg/km
Fire load  MJ/km
Apply
Reset
您的选择   14/14
Select all Items 耐克森产品编号 导线截面 (mm²) 导线直径 (mm) Minimum outer diameter (mm) Maximum outer diameter (mm) 近似重量 (kg/km) Fire load (MJ/km)
Make to order product 51710001 2.5 1.9 6.5 7.2 63 861
Make to order product 51710002 4 2.5 7.1 7.8 81 982
Make to order product 51710003 6 3.0 7.6 8.3 105 1081
Make to order product 51710004 10 4.1 9.1 9.5 160 1453
Make to order product 51710014 16 5.3 9.9 10.8 210 1537
Make to order product 51710005 25 6.5 11.0 11.9 295 1755
Make to order product 51710006 35 7.7 12.5 13.4 400 2120
Make to order product 51710007 50 9.5 14.2 15.3 555 2677
Make to order product 51710008 70 11.1 16.4 17.5 755 3285
Make to order product 51710009 95 12.9 18.2 19.3 965 3710
Make to order product 51710010 120 14.4 20.0 21.0 1205 4370
Make to order product 51710013 150 16.0 21.8 22.9 1475 4651
Make to order product 51710011 180 18.2 23.9 25.0 1795 5368
Make to order product 51710012 240 20.5 26.6 27.7 2300 6401
Add to favorites

 TOP
Characteristics : Smoke and Toxicity

Gas toxicity

Non-toxic  EN 50305,9 .2 Tocxicity index ≤3

 

 

Gas corrosivity

No corrosive EN 50267-2-2 pH≥4.3, Conductivity ≤10μS/mm 

 

 

Smoke density

Low smoke EN 61034-2 Light transmittance ≥70% 

 

 

Fire retardant

Fire retardant EN 50266-2-4 EN 50266-2-5 EN 50305, 9.1.2


Electrical characteristics

Electrical properties

 

 

Nominal voltage 

Uo/U (Umax) =

2000/3460 (4150) V 

Max. operating voltage in DC installations, 
one-sided earthed 

Vo =

3000V DC

Testing a.c. voltage (5 minutes) 

U =

10 kV

 

Max. operationg temperature at conductor

 

 

Conductor at normal operation

 

≤ 120 °C/ 100 000 h

 

≤ 140 °C/ 20 000 h

Conductor under short-circuit conditions(tinned)

≤ 250°C/ 5 s 

 

Operating in cold

 

 

Min. permissible ambient temperature

 

≥ -40 °C

 

Min. bending radii

 

Fixed installation:
Free moved : 
D= cable ø (mm)

≥ 4D
≥ 5D
                        


 TOP
相关信息
Y3000S NF F63-827 Single core   Rollling stock rating (55 kB)

耐克森 © 版权所有 2001 - 2012   相关条款 | 联系我们 | 站点地图