Applications
These wires combine the advantages of strictly halogen free, fire retardant, low smoke fume with a high performance insulation system.
They are recommended for extra high temperature applications in railway vehicles to transfer the power . Current carrying capacity acc. to EN 50343. Cabling rules acc. to EN 50355
Construction
- Conductor :
Flexible stranded tinned copper. Class 5 acc. to IEC 60228. Covered with separator tape
- Insulation :
Special cross-linked, halogen free. Silicone rubber
- Screen :
No
- Outer sheath :
Special cross-linked, halogen free. Silicone rubber
Bending factor when fixed installed : 4D
Bending factor when dynamic installed : 5D
Operating surroundings temperature: -40°C~115°C
Cable marking
FLAMEX SI – EN 50382-2 – 1800V– Conductor Size – Hazard Level (FF ) – 120°C – Nexans – Factory Code – Batch Number/Year
Core colours
Insulation: White (WT)
Sheath: Black (BK)
Standards applied
EN 50382-2
EN 45545-1
NF F16-101
|