CU XLPE Electric cable

Products

CU/XLPE/LSOH Cca 0.6/1kV 4×120 Recycled copper

Nexans ref. 3031286304195

  • Packaging: m
  • Conductor shape: Sector-shaped stranded (SM)
  • Neutral conductor section (when smaller): 120 mm²
  • Nominal conductor diameter: 12.3 mm
  • Nominal insulation thickness: 1.2 mm
  • Nominal outer sheath thickness: 2.3 mm
  • Fire retardant: IEC 60332-3-24 (cat C)

 

CU/XLPE/LSOH Cca 0.6/1kV 4×150 Recycled copper

Nexans ref. 3031286304196

  • Packaging: m
  • Conductor shape: Sector-shaped stranded (SM)
  • Neutral conductor section (when smaller): 150 mm²
  • Nominal conductor diameter: 13.9 mm
  • Nominal insulation thickness: 1.4 mm
  • Nominal outer sheath thickness: 2.4 mm
  • Fire retardant: IEC 60332-3-24 (cat C)

 

CU/XLPE/LSOH Cca 0.6/1kV 4×185 Recycled copper

Nexans ref. 3031286304197

  • Packaging: m
  • Conductor shape: Sector-shaped stranded (SM)
  • Neutral conductor section (when smaller): 185 mm²
  • Nominal conductor diameter: 15.3 mm
  • Nominal insulation thickness: 1.6 mm
  • Nominal outer sheath thickness: 2.6 mm
  • Fire retardant: IEC 60332-3-24 (cat C)

 

CU/XLPE/LSOH Cca 0.6/1kV 4×240 Recycled copper

Nexans ref. 3031286304198

  • Packaging: m
  • Conductor shape: Sector-shaped stranded (SM)
  • Neutral conductor section (when smaller): 240 mm²
  • Nominal conductor diameter: 17.2 mm
  • Nominal insulation thickness: 1.7 mm
  • Nominal outer sheath thickness: 2.8 mm
  • Fire retardant: IEC 60332-3-24 (cat C)

 

CU/XLPE/LSOH Cca 0.6/1kV 4×300 Recycled copper

Nexans ref. 3031286304199

  • Packaging: m
  • Conductor shape: Sector-shaped stranded (SM)
  • Neutral conductor section (when smaller): 300 mm²
  • Nominal conductor diameter: 19.6 mm
  • Nominal insulation thickness: 1.8 mm
  • Nominal outer sheath thickness: 3.0 mm
  • Fire retardant: IEC 60332-3-24 (cat C)

 

CU/XLPE/LSOH Cca 0.6/1kV 4×35 Recycled copper

Nexans ref. 3031286304191

  • Packaging: m
  • Conductor shape: Circular stranded (RM)
  • Neutral conductor section (when smaller): 35 mm²
  • Nominal conductor diameter: 7 mm
  • Nominal insulation thickness: 0.9 mm
  • Nominal outer sheath thickness: 1.8 mm
  • Fire retardant: IEC/EN 60332-3-24

 

CU/XLPE/LSOH Cca 0.6/1kV 4×400 Recycled copper

Nexans ref. 3031286304200

  • Packaging: m
  • Conductor shape: Sector-shaped stranded (SM)
  • Neutral conductor section (when smaller): 400 mm²
  • Nominal conductor diameter: 22.2 mm
  • Nominal insulation thickness: 2.0 mm
  • Nominal outer sheath thickness: 3.3 mm
  • Fire retardant: IEC 60332-3-24 (cat C)

 

CU/XLPE/LSOH Cca 0.6/1kV 4×50 Recycled copper

Nexans ref. 3031286304192

  • Packaging: m
  • Conductor shape: Circular stranded (RM)
  • Neutral conductor section (when smaller): 50 mm²
  • Nominal conductor diameter: 8.3 mm
  • Nominal insulation thickness: 1.0 mm
  • Nominal outer sheath thickness: 1.9 mm
  • Fire retardant: IEC 60332-3-24 (cat C)

 

CU/XLPE/LSOH Cca 0.6/1kV 4×70 Recycled copper

Nexans ref. 3031286304193

  • Packaging: m
  • Conductor shape: Sector-shaped stranded (SM)
  • Neutral conductor section (when smaller): 70 mm²
  • Nominal conductor diameter: 9.1 mm
  • Nominal insulation thickness: 1.1 mm
  • Nominal outer sheath thickness: 2.0 mm
  • Fire retardant: IEC 60332-3-24 (cat C)

 

CU/XLPE/LSOH Cca 0.6/1kV 4×95 Recycled copper

Nexans ref. 3031286304194

  • Packaging: m
  • Conductor shape: Sector-shaped stranded (SM)
  • Neutral conductor section (when smaller): 95 mm²
  • Nominal conductor diameter: 11.1 mm
  • Nominal insulation thickness: 1.1 mm
  • Nominal outer sheath thickness: 2.1 mm
  • Fire retardant: IEC 60332-3-24 (cat C)

 

Description

Description

Standards

  • Product
    2014/68/EU; EN 50575; IEC 60502-1
  • Test
    IEC 60332-3-22; IEC 60332-3-23; IEC 60332-3-24 Cat.C; IEC 60754-1; IEC 60754-2; IEC 61034

Application

For used in power transmission and distribution system.
They are mainly used in populated density area indoor applicationsin and public places with fire risk (hotels, schools, high-rise buildings, hospitals, data centers, airports, offices etc.) as well as electrical panels and control panels.
They are also well adapted to underground use in industrial applications where chemical and mechanical protections are needed (refinery areas, chemical plant…)

Construction

Conductor
Plain annealed copper conductor in accordance with IEC 60228,recycled copper.

Insulation
Extruded XLPE compound complied with IEC 60502-1

Identification:

  • 1 core : Nature
  • 2 cores Brown, Blue
  • 3 cores Brown, Black,Grey
  • 4 cores: Brown , Black, Grey, Blue
  • 3 cores: Brown, Blue, Green/Yellow
  • 4 cores: Brown , Black, Grey, yellow/green
  • 5 cores: Brow n , Black, Grey, Blue, Yellow/Green
  • Above 5C: White insulation with black numbers

Assembly and filler(if required)
The interstices between cores filled with non hygroscopic polypropylene yarn to form substantially circular shape with a suitable binder

Over sheath
Halogen Free Flame retardant HFFR/LSOH/LSZH polyolefin 
Color: Black

 

Features

UV resistance ,UL 1581 Sect.1200 Upon request
Oil resistance 70℃ 4 h Upon request
Anti termite and rodent Upon request

Electrical performance NEXANS 0.6/1kV CU/XLPE/PVC Power cable

No of cores and nominal cross section area
N × mm²]
Max.Conductor resistance DC at 20℃
Max. [Ω/km]
Voltage test
[kV/5min]
1.5 12.1 3.5
2.5 7.41 3.5
4 4.61 3.5
6 3.08 3.5
10 1.83 3.5
16 1.15 3.5
25 0.727 3.5
35 0.524 3.5
50 0.387 3.5
70 0.268 3.5
95 0.193 3.5
120 0.153 3.5
150 0.124 3.5
185 0.0991 3.5
240 0.0754 3.5
300 0.0601 3.5
400 0.0470 3.5
500 0.0366 3.5
630 0.0283 3.5
800 0.0221 3.5
1000 0.0176 3.5
1200 0.0151 3.5

 

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Conductor material
Copper
Conductor flexibility
Class 2
Insulation
XLPE
Material of filler / inner sheath
Yes
Outer sheath
Low smoke, zero halogen thermoplastic compound
With Green/Yellow core
No
With smaller neutral conductor
No

Dimensional characteristics

Dimensional characteristics

Earth conductor cross section
0 mm²

Electrical characteristics

Electrical characteristics

Rated Voltage Uo/U (Um)
0,6/1 kV
Test voltage
4 kV

Usage characteristics

Usage characteristics

Bending factor when laying
15 (xD)
Max. conductor temperature in service
90 °C
Maximum operating temperature
90 °C
Minimum installation temperature
-10 °C
Operating temperature, range
-15 ... 90 °C

Fire safety characteristics

Fire safety characteristics

Gases corrosivity
IEC 60754-2
Gases toxicity
IEC 61034, IEC 60754-2
Halogen free
IEC 60754-2

Resources

Resources

Selling & delivery Information

Cable marking

Inkjet print
NEXANS CU/XLPE/LSOH 0.6/1kV 4× 400 SQMM CE YY Cca-s1a,d0,a1 YYYY ****M 
 

 

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close