H1Z2Z2-K-1.5kV DC-1X4-10
H1Z2Z2-K-1.5kV DC-1X4-10
Single-core, multi-wire stranded tinned copper conductor power cables. These halogen-free and fire-safe cables are ideal for PV system applications. Thanks to their low smoke density, non-flame propagating properties and no corrosive gas emissions for protecting life and property in case of fire.
Read moreH1Z2Z2-K-1.5kV DC-1X4
Nexans ref. 3031277530122
- Conductor flexibility: Stranded class 5
- Type of conductor: Tinned stranded copper
- Conductor material: Tinned annealed copper
- Insulation colour: Natural
- Approximate weight: 0.059 kg/m
- Conductor cross-section: 4 mm²
- Nominal outer diameter: 5.7 mm
- Max. DC resistance of the conductor at 20°C: 5.09 Ohm/km
H1Z2Z2-K-1.5kV DC-1X6
Nexans ref. 3031277530123
- Conductor flexibility: Stranded class 5
- Type of conductor: Class 5
- Conductor material: Tinned annealed copper
- Insulation colour: Natural
- Approximate weight: 0.078 kg/m
- Conductor cross-section: 6 mm²
- Nominal outer diameter: 6.2 mm
- Max. DC resistance of the conductor at 20°C: 3.39 Ohm/km
H1Z2Z2-K-1.5kV DC-1X10
Nexans ref. 3031277530124
- Conductor flexibility: Stranded
- Type of conductor: Class 5
- Conductor material: Stranded tinned copper
- Insulation colour: On request
- Approximate weight: 0.121 kg/m
- Conductor cross-section: 10 mm²
- Nominal outer diameter: 7.3 mm
- Max. DC resistance of the conductor at 20°C: 1.95 Ohm/km
Description
Description
Standards
-
Product2014/68/EU; EN 50618; IEC 62930
-
TestIEC 60754-1; IEC 60754-2; IEC 61034
Application
Cables are designed to comply with the international standards of the solar plants. It is dedicated to the photovoltaic system
direct current (D.C.) side for permanent outdoor long-term use, under variable and harsh climate conditions.
These state of art 1.5kV D.C. crosslinked cables offer exceptional performances, easy installation and long-term reliability for
solar plant. They link photovoltaic panels for Utility-Scale solar plants or rooftops and also connect them to the array box (if
existing), or potentially to the inverter.
They are intended for permanent use outdoor and indoor, for free movable, free hanging and fixed installation. Installation
also in conduits and trunkings on, in or under plaster as well as in appliances. Suitable for the application in/at equipment
with protective insulation (protection class II).
Construction
- Conductor:Tinned flexible copper conductor,Class 5
- Insulation: cross-linked HFFR
- Sheath: cross-linked HFFR
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Dimensional characteristics
Dimensional characteristics
Electrical characteristics
Electrical characteristics
Usage characteristics
Usage characteristics
Resources
Resources
Selling & delivery Information