WDZA-BY(E6)-450/750V-1.5-25mm²

Products

H07Z1-R-450/750V-1X1.5-RED

Nexans ref. 30112774032016

  • Packaging: Coil (100m)
  • Conductor cross-section: 1.5 mm²
  • Nominal outer diameter: 3.15 mm
  • Max. DC resistance of the conductor at 20°C: 12.1 Ohm/km

 

H07Z1-R-450/750V-1X6-RED

Nexans ref. 30112774032326

  • Packaging: Coil (100m)
  • Conductor cross-section: 6 mm²
  • Nominal outer diameter: 4.85 mm
  • Max. DC resistance of the conductor at 20°C: 3.08 Ohm/km

 

H07Z1-R-450/750V-1X25-RED

Nexans ref. 30112774032402

  • Packaging: Coil (100m)
  • Conductor cross-section: 25 mm²
  • Nominal outer diameter: 8.7 mm
  • Max. DC resistance of the conductor at 20°C: 0.727 Ohm/km

 

H07Z1-R-450/750V-1X2.5-RED

Nexans ref. 30112774032321

  • Packaging: Coil (100m)
  • Conductor cross-section: 2.5 mm²
  • Nominal outer diameter: 3.75 mm
  • Max. DC resistance of the conductor at 20°C: 7.41 Ohm/km

 

H07Z1-R-450/750V-1X4-RED

Nexans ref. 30112774032362

  • Packaging: Coil (100m)
  • Conductor cross-section: 4 mm²
  • Nominal outer diameter: 4.25 mm
  • Max. DC resistance of the conductor at 20°C: 4.61 Ohm/km

 

H07Z1-R-450/750V-1X10-RED

Nexans ref. 30112774032331

  • Packaging: Coil (100m)
  • Conductor cross-section: 10 mm²
  • Nominal outer diameter: 6.3 mm
  • Max. DC resistance of the conductor at 20°C: 1.83 Ohm/km

 

H07Z1-R-450/750V-1X16-RED

Nexans ref. 30112774032339

  • Packaging: Coil (100m)
  • Conductor cross-section: 16 mm²
  • Nominal outer diameter: 7.1 mm
  • Max. DC resistance of the conductor at 20°C: 1.15 Ohm/km

 

Description

Description

Standards

  • Product
    EN 50525-3-41
  • Test
    IEC 60332-3 Cat.A; IEC 60754-1; IEC 60754-2; IEC 61034

Application

  • Indoor applications where fire safety is a priority (hotels, schools, high-rise buildings, hospitals, data centers, airports, offices, etc.)
  • Electrical panels and control panels
  • Wiring of indoor power and lighting circuits in dry environments

Construction

  • Conductor:copper
  • Insulation: TP HFFR

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Conductor flexibility
Stranded
Conductor shape
Circular
Type of conductor
Class 2
Conductor material
Bare copper
Insulation colour
Red

Dimensional characteristics

Dimensional characteristics

Approximate weight
0.021 kg/m
Number of cores
1

Electrical characteristics

Electrical characteristics

Rated Voltage Uo/U (Um)
450/750 V

Usage characteristics

Usage characteristics

Flame retardant
IEC 60332-3 Cat. A
Gases corrosivity
IEC 60754-1; IEC 60754-2
Max. conductor temperature in service
70 °C
Operating temperature, range
... °C
Smoke density
IEC 61034-2

Resources

Resources

Selling & delivery Information

Marking

NEXANS WDZA-BY(E6)-450/750V-1.5-25mm² YYYY ****M

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close